Diagnostic accuracy of troponin T measured ≥6h after symptom onset for ruling out myocardial infarction

English
Scandinavian cardiovascular journal : SCJ

Khoshnood, A., Erlandsson, M., Isma, N., Yndigegn, T. & Mokhtari, A.

Scandinavian cardiovascular journal : SCJ, 54(3), p. 153-161, 2020

Peer-reviewed

Abstract

Objectives Guidelines recommend a single high-sensitivity cardiac troponin T (hs-cTnT) ≤14 ng/L measured ≥6 h after chest pain onset combined with a GRACE score Design This was a secondary analysis of a prospective observational study, which enrolled emergency department (ED) chest pain patients. The hs-cTnT strategy was combined with HEART, TIMI, EDACS, GRACE score and ED physician’s overall assessment of patient history and ECG. The primary outcome was MI, and the secondary outcome was 30-day major adverse cardiac events (MACE). Results All tested diagnostic strategies were shown to have a negative predictive value (NPV) ≥99.5% for ruling out MI. Using HEART, TIMI, EDACS or ECG + patient history also resulted in a NPV ≥98% for ruling out 30-day MACE. An isolated hs-cTnT ≤14 ng/L measured ≥6 h after chest pain onset and the combination with GRACE score both had a NPV Conclusion A single hs-cTnT ≤14 ng/L obtained ≥6 h from chest pain onset, with and without GRACE score, reliably ruled out MI but did not perform well for ruling out 30-day MACE. These results question current guideline recommendations, and indicate that HEART, EDACS, TIMI, or ECG + patient history strategies should be the preferred risk stratification tools.